Customization: | Available |
---|---|
Transmission Type: | Manual |
Power: | Diesel |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
I. ASME Code | ||||||
Volume | 5m³ | 10m³ | 17.04m³ | 21.6m³ | 22m³ | 23.3m³ |
*Max. Payload |
2300kg
(2.5 t)
|
4600kg
(5 t)
|
7890kg
(8.52 t)
|
10000kg
(10.8 t)
|
10000kg
(11 t)
|
11110kg
(11.65 t)
|
Kerb Weight | - | - | - | 15560kg | 15170kg | 14800kg |
Gross Vehicle Weight | - | - | - | 25560kg | 25300kg | 26040kg |
Outline Dimension |
L:7482mm
W:2400mm
H:2640mm
|
L:8387mm
W:2400mm
H:2690mm
|
- |
L:9945mm
W:2500mm
H:3550mm
|
L:10130mm
W:2500mm
H:3550mm
|
L:10340mm
W:2490mm
H:3650mm
|
Design Pressure | 1.724MPa | 1.724MPa | 1.724MPa | 1.724MPa | 1.724MPa | 1.724MPa |
Design Temperature | 50ºC | 50ºC | 50ºC | -20/50ºC | 50ºC | -23.3/51.7ºC |
Corrosion Allowance | 1 mm | 1 mm | 1 mm | 1 mm | 1 mm | 0 |
Material of Shell | SA-516 | SA-516 | SA-612 | SA-612 | SA-612 | SA-612 |
Material of Head | SA-516 | SA-516 | SA-612 | SA-612 | SA-612 | SA-612 |
Test Pressure
(Hydraulic Horizontal)
|
2.25MPa | 2.25MPa | 2.25MPa | 2.25MPa | 2.25MPa | 2.25MPa |
Air Test Pressure | 1.724MPa | 1.724MPa | 1.724MPa | 1.724MPa | 1.724MPa | 1.724MPa |
*Please note that different medium component will cause different density and different payload.
**Please contact for more different kinds of capacity and standard tanks.
|
II. Chinese GB Standard | |||||
Capacity | 10m³ | 13.58m³ | 20m³ | 23.81m³ | 36m³ |
*Max. Payload |
4200kg
(5 t)
|
5700kg
(6.79 t)
|
8400kg
(10 t)
|
10000kg
(11.905 t)
|
15120kg
(18 t)
|
Kerb Weight | 10800kg | 10170kg | 15300kg | 15320kg | 15750kg |
Gross Vehicle Weight | 15130kg | 16000kg | 23700kg | 25450kg | 31000kg |
Outline Dimension |
L:8830mm
W:2490mm
H:3050mm
|
L:8140mm
W:2450mm
H:3450mm
|
L:11800mm
W:2495mm
H:3937mm
|
L:10040mm
W:2490mm
H:3580mm
|
L:11980mm
W:2500mm
H:3770mm
|
Design Pressure | 1.61/-0.1 MPa | 1.61/-0.1 MPa | 1.61/-0.1 MPa | 1.61/-0.1 MPa | 1.61 MPa |
Design Temperature | 50ºC | 50ºC | -20/50ºC | 50ºC | -20/50ºC |
Corrosion Allowance | 1 mm | 1 mm | 1 mm | 1 mm | 1 mm |
Material of Shell | Q345R | Q345R | Q345R | Q345R |
Q420R
(WH590D)
|
Material of Head | Q345R | Q345R | Q345R | Q345R | Q345R(N) |
Thickness of Shell | 9mm | 10.5mm | 9.5mm | 12mm | 9.8mm |
Thickness of Head | 10mm | 11mm | 10mm | 13mm | 8mm |
Hydraulic Test Pressure | 2.10MPa | 2.10MPa | 2.10MPa | 2.10MPa | - |
Pressure of Leak Test | 1.61MPa | 1.61MPa | 1.61MPa | 1.61MPa | - |